1×64 SC/APC PLC Splitter For Passive Optical Distribution

Send Inquiry
1×64 SC/APC PLC Splitter For Passive Optical Distribution
Details
Bring one optical feed to 64 output paths with an SC/APC connectorized module. The FOCC SPT-NP-1X64R-A-2M combines G.657.A1 fiber, an enclosed splitter body and individually numbered output leads for integration into a planned optical distribution assembly. Choose this configuration when the mating ports require SC/APC and the network design allows for a 1×64 split. Its inspection specification lists insertion loss of ≤20.40 dB and return loss of ≥55 dB. A serial-numbered sample record provides output-port results at 1310, 1490 and 1550 nm for technical review.
Category
MTP MPO Cable Assembly
Share to
Description

Welcome to buy the 1×64 sc/apc plc splitter for passive optical distribution with our factory. As one of the leading manufacturers and suppliers in China, we also welcome the customized orders. Consult the price and the quotation with us now.

 

Start with the Interface Your Network Uses

The SC/APC termination is the defining choice for this module. It needs to match the connector finish on the equipment, patch panel or distribution assembly it connects to. SC/APC and SC/UPC use different end-face geometries and should not be mated directly, even though both use the SC connector format.

 

For this APC configuration, the inspection record specifies return loss of at least 55 dB. Return loss describes how much light is reflected back: a higher positive return-loss value means less reflected power under the same measurement conditions. It does not describe the power lost through the splitter, which is assessed separately as insertion loss.

 

If the receiving ports are SC/UPC, specify an SC/UPC splitter configuration. Select the connector finish from the actual mating interface and the project's reflection requirements; changing to APC alone does not establish a lower insertion loss or a longer transmission distance.

 

Allow for the 1×64 Split in the Optical Budget

A 64-way split allocates the available input power across many branches. For an ideal equal splitter, the division alone corresponds to approximately 18.06 dB, calculated as 10 × log₁₀(64). A real assembly has additional loss, so this theoretical value is not the figure to use as the product's maximum insertion loss.

 

The inspection specification for this module lists 20.40 dB maximum insertion loss. Use the agreed maximum for the ordered assembly when allocating the splitter's share of the optical budget. Add fiber attenuation, splices, any connections outside the splitter measurement boundary and the required design margin.

 

For illustration, if a system has a 28 dB optical budget and 20.40 dB is allocated to this splitter, 7.60 dB remains for the other path losses and design margin. This is a planning example, not a qualified reach or PON-class claim for the product. Confirm whether connector losses are already included in the splitter test before adding them again.

 

A single 1×64 module and a cascaded 1×4 plus 1×16 arrangement can both produce 64 final branches, but their installation layouts and loss calculations differ. In a fully populated cascade, one first-stage 1×4 feeds four second-stage 1×16 splitters; each final path crosses two splitters. Add the specified losses for both stages and the intermediate connections when evaluating that alternative.

 

When a lower split count is being considered, review the FOCC 1×32 fiber splitter against its own configuration and loss specification. Choose the split count from the network layout and available budget rather than the output count alone.

 

What the SC/APC Sample Record Shows

The inspection record dated 7 July 2026 identifies S/N 26070700125 and lists Port 1 through Port 64 at three wavelengths. The module label in the corresponding product photographs carries the same serial number.

Review point Reported result for this sample How to use it
Highest insertion loss at 1310 nm 20.28 dB Compare with the 20.40 dB report limit
Highest insertion loss at 1490 nm 20.28 dB Compare with the 20.40 dB report limit
Highest insertion loss at 1550 nm 20.29 dB Compare with the 20.40 dB report limit
Output uniformity 0.48 dB at each test wavelength Review the difference between highest and lowest output loss
Output return loss Pass at all three wavelengths against ≥55 dB A pass result is recorded; individual numerical RL readings are not supplied

 

These figures describe the identified sample, not a guaranteed result for every delivered unit. The record supports review at the three listed wavelengths; it does not establish a continuous spectral measurement across the full operating range.

 

For an order with a specific acceptance procedure, state the required wavelengths, maximum loss, reflection criteria and documentation. Agree these alongside the test reference method and the treatment of connector losses.

 

Match the Module to the Enclosure and the Order

 

The reported package size is 141 × 115 × 18 mm. The surrounding enclosure also needs room for the lead bundle, connector access and permitted fiber routing. Check the dimensional drawing and fixing arrangement before allocating space in a cabinet or distribution box.

Ordering detail Configuration listed in the inspection record
Part number SPT-NP-1X64R-A-2M
Split configuration 1×64
Connector type SC/APC
Fiber type G.657.A1
Operating wavelength 1260–1650 nm
Fiber length ≥2.0 m
Package dimensions 141 × 115 × 18 mm
Operating / storage temperature −40 to +85°C
Maximum insertion loss 20.40 dB
Maximum polarization-dependent loss 0.40 dB
Minimum return loss 55 dB
Maximum output uniformity 2.0 dB
Directivity >55 dB

The length entry does not define separate input and output tolerances. Specify those lengths, their measurement reference points and the required tolerances in the enquiry. The dimensions above describe the reported package, not the shipping carton.

 

The temperature range is a report-listed specification. Enclosure sealing, environmental qualification and connector protection must be assessed for the intended installation; this optical inspection record does not establish an outdoor ingress-protection rating.

 

 

Keep the Port Map with the Receiving Record

The product photographs show an IN sleeve identifying the input and numbered sleeves on the output leads. During assembly, assign each output to the project port schedule and retain that mapping with the installation records. A branch identifier is useful only when the field record and the physical lead refer to the same connection.

 

At receipt, compare the part number and connector configuration with the order, then match the unit's serial number to the accompanying inspection document where one is required. Check that the agreed test wavelengths and acceptance limits appear on that document before releasing the assembly for installation.

 

The photographed packing uses a carton with coiled leads and connector ends separated in foam slots. Inspect the connector protection and visible lead condition before unpacking. Define the pack quantity, label format and required unit-level documents with the order so the receiving team knows what to check.

 

7

Lead identification on illustrated unit S/N 26070700124. Its separate test record is not shown here.

8

Photographed carton. Agree pack quantity and labeling for the order.

 

 

Questions About Selecting a 64-Way SC/APC Splitter

 

Can this 1×64 PLC splitter be specified for a GPON or XGS-PON project?

Evaluate it against the exact system requirements. The record lists a 1260–1650 nm operating range, but its measured results are at 1310, 1490 and 1550 nm. It does not provide dedicated measurements at 1270 and 1577 nm for an XGS-PON assessment. Confirm the required wavelength performance, optical budget and acceptance criteria before approving it for a particular PON design.

 

Does a 1×64 splitter replace an OLT port or guarantee service for 64 subscribers?

It provides 64 passive optical output paths from one input. It does not add active OLT capacity or allocate bandwidth. The number of supported subscribers depends on the OLT configuration, ONU compatibility, service design and the complete optical budget.

 

Does SC/APC reduce the splitting loss?

The connector finish addresses the mating interface and reflection behavior. The loss caused by dividing power across 64 outputs remains part of the optical budget. This module's report lists a 20.40 dB insertion-loss limit separately from its ≥55 dB return-loss requirement.

 

Can the ≥55 dB return-loss requirement be used as an actual measured value?

No. The report marks the output ports Pass against that requirement, without giving individual numerical return-loss readings. If your acceptance process requires measured RL values rather than pass/fail records, include that requirement in the order review.

 

How should the factory inspection requirements be written?

Name the ordered part number, connector finish, test wavelengths and optical limits. Define the port numbering and serial-number relationship to the report. Where required, request confirmation of connector end-face inspection criteria, test equipment calibration and component traceability. Agree the available evidence and document format before production release.

07Enquiry

 

Hot Tags: 1×64 sc/apc plc splitter for passive optical distribution, China, factory, suppliers, manufacturers, quotation, customized, price, buy

Send Inquiry