Welcome to buy the 400x fiber endface inspection microscope / fiber optic end face inspector with our factory. As one of the leading manufacturers and suppliers in China, we also welcome the customized orders. Consult the price and the quotation with us now.
400X magnification for a closer look before connection
Dust, oil, scratches and polishing defects on a fiber connector end face are difficult to judge reliably with the naked eye. This 400X fiber endface inspection microscope displays the end-face image on an integrated screen and uses manual focusing for visual inspection during assembly, maintenance, incoming inspection and laboratory work.
The supplied specification sheet lists an analog PAL video format, RCA image input and output, and an 8-inch TFT display with 800 × 600 resolution. For teams that still use compatible analog video equipment or need a larger screen at a shared inspection bench, the product provides a direct way to view the connector end face before it is mated.
At-a-glance benefits
● 400X magnification:Enlarges the fiber connector end face for visual inspection.
● Integrated 8-inch display:The supplied PDF lists an 8-inch TFT display with 800 × 600 resolution for easier viewing at a workbench.
● Manual focus:Lets the operator adjust image clarity for each connector and inspection position.
● Adjustable viewing mechanism:The supplied table includes X/Y adjustment information; the exact adjustment capability must be confirmed for the shipping model.
● Analog PAL and RCA interfaces:The PDF lists analog video input/output and RCA ports for connection to compatible display or capture equipment.
● Benchtop enclosure:The front panel combines the display, inspection port and control keys in a fixed-workstation format.
What the microscope helps you check
A fiber connector end face is small enough that contamination or damage can be missed during a quick visual check. Connecting an uninspected end face can transfer contamination into an adapter or allow an existing scratch, chip or polishing defect to remain in the link. An inspection microscope moves that decision earlier in the workflow.
Typical use cases include:
- Connector and patch-cord release inspection:Check end faces before shipment or mating to reduce the chance of visible contamination or damage entering the delivered assembly.
- Fiber assembly and rework:Observe the end face after assembly, cleaning, polishing or repair.
- ODF, patch-panel and data-room maintenance: Use visual inspection as part of fault investigation and preventive maintenance.
- Incoming inspection and supplier quality review:Add a repeatable visual check for connectors, patch cords, adapters and fiber assemblies.
- Laboratory and operator training:Display the end-face image on a larger screen for demonstrations and basic inspection practice.
The microscope provides image observation. It does not replace connector cleaning, end-face acceptance criteria, insertion-loss/return-loss testing or a qualified technician's decision. A 400X label alone does not create an automatic pass/fail result.
Product value in the actual inspection workflow
See the end face instead of relying on a quick visual guess
400X magnification allows the operator to view the connector end-face area on the display. The usable field of view, image clarity and visible defect range will also depend on the adapter, optical condition, lighting, cleanliness and focusing method. Final acceptance should therefore be based on an actual image check with the intended connector and adapter.
Manual focus for connector-by-connector inspection
The supplied PDF lists the focus mode as Manual. Manual focus is suitable for an operator who inspects individual connectors and adjusts the image for the actual end-face position. Buyers who need automated, high-volume pass/fail analysis should confirm whether a different software or model version is available.
An integrated screen for shared viewing
The PDF lists an 8-inch TFT display with 800 × 600 pixels. A larger integrated screen can be useful at a repair bench, laboratory station or training table where a second person needs to see the same inspection image. The actual image quality should be evaluated with the target connector and adapter before volume purchase.
Analog video interfaces for existing equipment
The specification sheet lists Analog PAL as the image input/output format and RCA for both image input and output. This may be useful where a compatible analog monitor, video recorder or capture device is already installed. Confirm the local video standard, signal direction, RCA cable and external equipment compatibility before ordering.
A fixed-workstation format
The images show a benchtop enclosure with side ventilation openings, a front display, an inspection port and front-panel keys. Image 05.jpg marks the body at approximately 27 × 19 × 16 cm and approximately 1.7 kg. The PDF table separately lists 288 × 230 × 190 mm and 5 kg. These two sets of values must be matched to the correct model, measurement method or net/gross-weight definition before they are used for a quotation, shipping calculation or storage plan.
Recommended inspection procedure
Step 1: Confirm the connector adapter and video system
Select the inspection adapter that matches the connector under test and confirm that the PAL/RCA display path is connected. The supplied files do not identify the adapter range or standard adapter quantity, so the equipment should not be assumed to cover every FC, SC, LC, ST, MPO/MTP or other connector type.
Step 2: Clean before inspection
Use a connector-cleaning tool appropriate for the end face to remove loose dust and oil. Do not use the microscope as a substitute for cleaning, and do not mate a connector of unknown cleanliness with a network device or reference adapter.
Step 3: Secure the connector and focus manually
Install the connector securely in the correct adapter. Turn on the unit and adjust the manual focus until the end-face image is clear. If the shipping model includes the relevant axis adjustment, center the end face in the image before judging its condition.
Step 4: Inspect and record
Look for visible contamination, scratches, chips, abnormal polishing marks or other conditions that may affect contact. For incoming inspection or production sampling, record the sample ID, connector type, cleaning action, image result and reinspection decision.
Step 5: Clean or rework, then reinspect
If contamination is found, clean the connector and inspect it again. If a scratch, chip or polishing concern remains, isolate the sample and follow the applicable connector acceptance procedure. "Cleaned" and "accepted" are separate decisions.
Technical specifications supported by the supplied files
| Item | Information in the supplied files | Evidence and publishing guidance |
|---|---|---|
| Product type | Fiber microscope / fiber endface inspection microscope | Visible in the product images and PDF; may be used directly |
| Magnification | 400X | Appears in the images and PDF; may be used directly |
| Focus mode | Manual | Listed in the PDF; may be used directly |
| Image format | Analog PAL | Listed in the PDF; confirm regional video compatibility |
| Image output port | RCA | Listed in the PDF; may be used with a compatibility note |
| Image input port | RCA | Listed in the PDF; confirm exact signal function |
| CCD | 1/3 inch, 420 lines | Listed in the PDF; confirm the complete CCD and effective imaging data |
| Image analysis | - in the PDF | Do not describe the product as an automatic image-analysis or pass/fail system |
| Display | 8-inch TFT, 800 × 600 pixels | Listed in the PDF; may be used directly |
| Power consumption | 3 W | Listed in the PDF; confirm the test condition and power configuration |
| Power supply | DC12 | Listed in the PDF; confirm input tolerance, adapter and plug type |
| Operating temperature | +10°C to +50°C | Listed in the PDF; may be used with a source note |
| Storage temperature | 0°C to +55°C | Listed in the PDF; may be used with a source note |
| Body dimensions | Approx. 27 × 19 × 16 cm in the image; 288 × 230 × 190 mm in the PDF | Values conflict; confirm the applicable model and measuring basis |
| Weight | Approx. 1.7 kg in the image; 5 kg in the PDF | Confirm net weight, gross weight or model difference |
| Carton size | Approx. 30 × 30 × 20 cm in the image | Confirm with the final packed shipment |
| Visible accessories | Power-supply accessories and a small accessory labelled LC Port are visible in image 011.jpg | Confirm the LC accessory function, included adapters, power-supply details and quantities on the packing list |
| Connector adapter range | Not stated in the supplied files | Must be confirmed before quotation |
| Calibration or inspection report | Not stated in the supplied files | Confirm whether a factory inspection record or calibration document is supplied |
| Warranty and service | Not stated in the supplied files | Add the supplier's formal policy before publication |
Ten questions to confirm before purchase
- Is 400X the actual optical magnification, a display magnification or a system-level nominal value?
- Does the shipping model include X/Y adjustment? The PDF table appears to show both a non-adjustable and a Y-axis-adjustable configuration.
- Which connector adapters are supported: FC, SC, LC, ST, MPO/MTP or other types?
- Are the adapters included in the standard package or selected separately by connector type?
- What are the exact functions and signal directions of the RCA input and output? Is the output composite PAL video?
- Does the unit support image freeze, screenshots, external recording or computer capture? These functions are not listed in the supplied files.
- What are the DC12 input requirements, supplied power-adapter specification and plug standard?
- Do 1.7 kg and 5 kg refer to net weight, gross weight or different models?
- Do 27 × 19 × 16 cm and 288 × 230 × 190 mm refer to different models or different measurement references?
- Can the supplier provide the manual, factory inspection record, warranty terms, service process and spare-adapter list?
Frequently asked questions
Is this an automatic fiber endface inspection system?
The supplied PDF lists image analysis as - and focus mode as manual. This page therefore positions the product as a 400X visual fiber endface inspection microscope, not as an automatic contamination-recognition or automatic PASS/FAIL system. If the project requires automated analysis, ask whether a different software package or model is available.
Does 400X describe the inspection accuracy?
No. 400X describes magnification. It does not, by itself, specify defect-classification accuracy, field of view, optical resolution, illumination uniformity or compliance with an end-face acceptance standard. Confirm the imaging performance with the intended connector and adapter.
Can the unit inspect every fiber connector type?
This cannot be confirmed from the current files. A microscope requires a compatible adapter or fixture for the connector under test. List the connector types and end-face forms in the inquiry and confirm the adapter coverage and included quantities.
Can it connect to an external display or capture device?
The PDF lists analog PAL input/output and RCA ports, which indicates an analog video path. Direct connection depends on video standard, signal direction, cable and external equipment compatibility. Confirm these details before integrating the microscope into an existing system.
Can the unit decide whether an end face is acceptable?
The microscope helps the operator view the end face. Acceptance still depends on the connector type, the applicable end-face criteria and the company's inspection procedure. Cleaning, visual inspection and insertion-loss/return-loss testing should be treated as related but separate steps.
Product Positioning
| Buyer concern | Common positioning in higher-end systems | Evidence-based positioning for this product |
|---|---|---|
| Inspection method | Automatic focus, analysis and pass/fail decision | 400X magnification, manual focus and integrated-screen viewing |
| Display | Handheld probe connected to a mobile device or software | 8-inch TFT display for a shared benchtop inspection view |
| System interface | Digital images, reports and data management | Analog PAL with RCA input/output; compatibility must be confirmed |
| Use case | Fast field inspection with data traceability | Visual inspection for assembly, maintenance, incoming inspection, laboratory work and training |
| Purchase priority | Software, standards library, reports and integration | Adapter coverage, image quality, video compatibility, actual size/weight and delivered accessories |
Hot Tags: 400x fiber endface inspection microscope / fiber optic end face inspector, China, factory, suppliers, manufacturers, quotation, customized, price, buy