Welcome to buy the 96f 1u fixed mpo-lc fiber optic patch panel for high-density rack cabling with our factory. As one of the leading manufacturers and suppliers in China, we also welcome the customized orders. Consult the price and the quotation with us now.

Product Positioning
This product is suitable when your project needs:
A 1U rack-mount fiber panel for standard 19-inch cabinets
Up to 96 fibers in a compact front patching area
MPO trunk cable access with LC front distribution
Clear front port numbering for easier fiber tracing
A fixed metal structure for stable rack installation
A panel that can be customized by adapter type, capacity, color and loading method
This product is not just an empty fiber box.
The front panel is already designed around numbered fiber distribution, while the inside provides MPO-labeled routing positions. This makes it more suitable for project deployment than a generic blank rack enclosure.
Core Specifications
| Item | Specification |
|---|---|
| Product Name | 96F 1U Fixed MPO-LC Fiber Optic Patch Panel |
| Reference Model | HDF-GD-010-1U |
| Installation | 19-inch rack mount |
| Rack Height | 1U |
| Fiber Capacity | Up to 96 fibers in LC configuration |
| Front Adapter Type | LC duplex adapter shown in product photos |
| Adapter Options | SC / LC options depending on capacity requirement |
| Panel Type | Fixed rack-mount fiber distribution panel |
| Main Function | Fiber connection, protection, routing and cable management |
| Material | Cold-rolled steel or galvanized steel plate |
| Surface Treatment | Anti-static epoxy powder coating |
| Color Options | RAL9004 black / RAL7035 grey white |
| Product Size | Approx. 424 x 151 x 44.5 mm, based on supplied specification sheet |
| Operating Temperature | -10°C to +45°C |
| Storage Temperature | -40°C to +70°C |
| Relative Humidity | 85% at +30°C |
| Applications | IDC, telecom room, FTTH build, LAN/WAN |
Parameter note for publishing:
The supplied specification sheet lists the size as 424 mm, 151 mm and 44.5 mm. Before final publishing, confirm whether 424 mm is depth or width according to the factory drawing, because standard rack products are often described differently by different factories.
Capacity Selection Guide
| Capacity | SC Adapter | LC Adapter | Recommended Use |
|---|---|---|---|
| 12F | Available | Available | Small cabinet, access point, low-density fiber distribution |
| 24F | Available | Available | Telecom room, building fiber access |
| 48F | Available | Available | Medium-density rack cabling |
| 96F | Not recommended in this spec | Available | High-density 1U fiber distribution |
| 120F | Not listed | Not listed | Need separate confirmation |
For this product page, the recommended configuration is 96F with LC adapters, because LC supports higher density in 1U space. If the customer needs SC ports, 12F, 24F or 48F versions are more practical according to the current specification sheet.
Front Panel Design: Clear 1-96 Port IdentificationThe front panel is marked from 1 to 96, allowing installers to identify each fiber channel quickly during connection, testing and maintenance. This is important in data center and telecom room projects where multiple patch cords may be managed in the same rack. The photos show blue LC duplex adapters installed on the front panel, with white dust caps protecting the adapter interfaces. The numbered layout helps technicians record the port map and reduce mistakes during patching. Buyer decision value: Easier port documentation during project installation Faster fiber route tracing during maintenance Reduced risk of wrong patching in high-density racks Cleaner handover for contractors and network operators |
|
Front Panel Design: Clear 1-96 Port Identification
The front panel is marked from 1 to 96, allowing installers to identify each fiber channel quickly during connection, testing and maintenance. This is important in data center and telecom room projects where multiple patch cords may be managed in the same rack.
The photos show blue LC duplex adapters installed on the front panel, with white dust caps protecting the adapter interfaces. The numbered layout helps technicians record the port map and reduce mistakes during patching.
Buyer decision value:
- Easier port documentation during project installation
- Faster fiber route tracing during maintenance
- Reduced risk of wrong patching in high-density racks
- Cleaner handover for contractors and network operators


MPO Trunk Cable Routing Area
Inside the panel, the MPO connection area is labeled MPO 1, MPO 2, MPO 3 and MPO 4. This helps installers organize trunk cable input and match internal routing with the front LC distribution area.
For projects using MPO trunk cables, this design can reduce field termination workload and make rack-side fiber distribution more structured. The side entry design also gives space for cable routing into the chassis.
Suitable for projects involving:
- MPO trunk cable deployment
- Pre-terminated fiber cabling
- Data center cabinet interconnection
- High-density LC front patching
- Faster installation compared with field fusion-only cabling
Fixed 1U Metal Chassis for Rack Installation
The chassis is made from cold-rolled steel or galvanized steel plate, with anti-static epoxy powder coating. The product shown in the photos is black, matching the RAL9004 black option in the specification sheet.
The fixed rack-mount design is suitable for cabinets where the fiber distribution point does not need frequent sliding access. It provides a stable mounting structure and keeps the fiber connection area protected after installation.
Structural points visible from the photos:
- 1U low-profile rack design
- Metal chassis with black powder-coated surface
- Rack mounting ears on both sides
- Internal cable routing space
- Removable/open panel structure for installation access
- Side cable entry and cable management area

Customization Options
This product can be configured according to project requirements.
| Custom Item | Available Options |
|---|---|
| Adapter Type | LC / SC, depending on capacity |
| Fiber Capacity | 12F / 24F / 48F / 96F |
| Color | RAL9004 black / RAL7035 grey white |
| Material | Cold-rolled steel / galvanized steel plate |
| Loading Method | Empty panel / partially loaded / fully loaded |
| Port Labeling | Standard numbering or project-specific label |
| MPO Layout | MPO position marking can be configured according to project need |
| Packaging | Standard carton packing or project packing requirement |
Procurement note:
If the buyer is not sure which configuration to choose, they should provide cabinet size, fiber count, adapter type, cable type, MPO trunk quantity and target application. This helps the factory recommend the correct structure before production.
Quality Control and Inspection Capability
For this type of rack-mount fiber distribution panel, quality inspection should not only check appearance. The key is whether the product can be installed smoothly, hold adapters firmly and support practical cable management.
Suggested QC points before shipment:
- Chassis surface coating inspection
- Rack ear and mounting hole alignment check
- Front panel numbering clarity check
- Adapter installation firmness check
- MPO label position check
- Side cable entry and internal routing space inspection
- Screw and accessory completeness check
- Carton and foam protection inspection
- Sample photo confirmation before batch shipment if required
For loaded versions, additional checks can include:
- Adapter type confirmation
- Adapter quantity confirmation
- Port layout confirmation
- Dust cap completeness
- Fiber routing or pre-termination check if supplied as a pre-loaded assembly
This makes the product easier for project buyers to approve before shipment and reduces installation issues after delivery.
FAQ

What is the main use of this 96F 1U MPO-LC patch panel?
It is used for high-density fiber connection, protection and cable management in 19-inch rack systems. It is suitable for data centers, telecom rooms, FTTH projects and LAN/WAN fiber cabling.
Why is LC recommended for the 96F version?
LC adapters are smaller than SC adapters, so they are more suitable for high-density 1U fiber distribution. According to the supplied capacity table, the 96F configuration is listed under LC.
Can this panel be used with MPO trunk cables?
Yes. The product photos show internal MPO-labeled positions marked MPO 1 to MPO 4, which are designed to help organize MPO trunk cable routing and connection.
What information should I provide before ordering?
To confirm the right configuration, buyers should provide fiber capacity, adapter type, cable type, MPO trunk quantity, rack environment, color requirement and whether the panel should be empty, partially loaded or fully loaded.
Can you provide a loaded version with adapters installed?
Yes, the product can be supplied empty, partially loaded or fully loaded according to project requirements. The shown sample includes LC duplex adapters on the front panel.
What should be checked before shipment?