Welcome to buy the fullaxs lc/upc uniboot single mode fiber patch cable for rrh and ftta applications with our factory. As one of the leading manufacturers and suppliers in China, we also welcome the customized orders. Consult the price and the quotation with us now.
Designed for Compact FTTA and RRH Equipment Connections
In FTTA and RRH networks, the most critical fiber connection is often not inside the main distribution frame, but directly at the equipment side. Radio units, AAU equipment, BBU/RRU links, outdoor wireless devices, and base station cabinets all require a fiber patch cable that can connect reliably in a compact and demanding installation area.
The FULLAXS LC/UPC Uniboot to LC/UPC Single Mode Patch Cable is designed for these equipment-side fiber links. One end uses a rugged FullAXS interface for outdoor telecom equipment, while the LC/UPC side supports connection to optical modules, distribution units, or cabinet-side fiber ports. This makes the cable suitable for FTTA projects where the link must remain stable after installation, even when the equipment is exposed to outdoor operation, vibration, frequent inspection, or limited service space.
For RRH, AAU, and BBU/RRU interconnection, the cable helps create a more direct and controlled fiber path between active equipment and the optical access point. Instead of using a general indoor patch cord in a demanding outdoor wireless environment, this product provides a dedicated connection option for base station deployment, equipment upgrades, and field maintenance.
Its value is especially clear in projects where installers need fast mating, stable optical performance, and better service access around the device. The compact cable structure supports easier handling during installation, while the FullAXS interface helps improve connection reliability at the outdoor equipment side. For contractors and system integrators, this means fewer compatibility concerns, cleaner project execution, and a more professional FTTA cabling solution.

LC/UPC Uniboot Design for Cleaner Cable Routing
The FULLAXS LC/UPC Uniboot to LC/UPC Single Mode Patch Cable adopts an LC/UPC Uniboot structure, allowing duplex fibers to be integrated into a more compact cable design. Compared with two separate duplex cable legs, the Uniboot design is more suitable for port-dense and space-limited equipment areas. It helps reduce cable occupancy and keeps the routing around the port area cleaner and more organized.
For field installers, the value of this design is practical and direct: the cable is easier to manage, the link is easier to identify, and adjacent ports are less likely to be disturbed during maintenance. In RRH, AAU, BBU/RRU interconnection, outdoor wireless equipment, and base station cabinets, clear cable routing can effectively reduce maintenance difficulty when fiber links need to be inspected, replaced, or adjusted frequently.
FOCC can customize the cable length, fiber type, jacket material, connector configuration, label, and packaging according to different base station, telecom cabinet, and outdoor wireless deployment requirements.
Fiber Type Comparison Table
| Fiber Type | Suitable Applications | Main Advantages | Bending Performance | Suitable for This Product? |
|---|---|---|---|---|
| G.652.D Single Mode | Long-distance transmission, backbone networks, metro networks, standard single mode links | High compatibility, widely used, cost-effective | Standard bending performance; not ideal for very tight bending radius | Usable, but not recommended as the first choice |
| G.657.A1 Bend Insensitive SM | FTTA, RRH, base station cabinets, compact equipment-side routing | Compatible with G.652.D networks while offering better bending resistance | Designed for a minimum bending radius of 10 mm under ITU-T recommendations | Recommended as the main configuration |
| G.657.A2 Bend Insensitive SM | Tighter routing spaces, internal equipment cabling, compact cabinets | Better bending performance than G.657.A1 in smaller routing areas | Designed for a minimum bending radius of 7.5 mm under ITU-T recommendations | Suitable as a premium customization option |
| G.657.B3 Bend Insensitive SM | Extremely tight bending radius, short indoor terminal connections | Stronger bending resistance for highly compact routing | Designed for a minimum bending radius of 5 mm under ITU-T recommendations | Not recommended as the standard option unless required by special projects |
Recommended Fiber Type for FTTA Equipment-Side Routing
For compact FTTA, RRH, AAU, and base station cabinet connections, FOCC recommends G.657.A1 bend-insensitive single mode fiber as the standard configuration for this FULLAXS LC/UPC Uniboot patch cable. Compared with conventional G.652.D single mode fiber, G.657.A1 provides better bending-loss control in space-limited routing areas while maintaining compatibility with G.652.D-based single mode networks.
For projects with tighter routing paths or more demanding cable management requirements, G.657.A2 can also be selected as an optional fiber grade. For general telecom links where bending stress is not a key concern, G.652.D remains available as a cost-effective option.
| Technical Data | FULLAXS LC/UPC Uniboot-LC/UPC Patch Cable SM |
|---|---|
| Cable Assembly Type | Rugged FullAXS to LC/UPC Uniboot fiber patch cable |
| Fiber Mode | Single Mode |
| Fiber Size | 9/125μm |
| Recommended Fiber Grade | G.657.A1 bend-insensitive single mode fiber |
| Optional Fiber Grade | G.652.D / G.657.A2 |
| Connector Side A | FULLAXS LC/UPC |
| Connector Side B | LC/UPC Uniboot |
| Fiber Count | Duplex, 2 fibers |
| Polishing Type | UPC |
| Insertion Loss | ≤0.3dB typical low-loss option; ≤0.5dB standard project option |
| Return Loss | ≥50dB for single mode UPC |
| Operating Wavelength | 1310nm / 1550nm |
| Jacket Material | LSZH, TPU, or customized outdoor jacket |
| Application Environment | FTTA, RRH, AAU, BBU/RRU, outdoor wireless equipment, base station cabinet |
| Test Items | Insertion loss, return loss, polarity, end-face quality, visual inspection |
| Customization | Cable length, fiber type, jacket color, label, packaging, connector configuration |
Purchase Recommendation
For FTTA, RRH, AAU, BBU/RRU, and outdoor wireless equipment connections, the FULLAXS LC/UPC Uniboot to LC/UPC Single Mode Patch Cable is recommended when the installation area is compact, the equipment ports are dense, and cable routing needs to remain clean and easy to maintain.
If your project requires a short or customized equipment-side fiber connection, this cable is a practical choice. The FullAXS interface supports rugged outdoor telecom equipment connection, while the LC/UPC Uniboot design helps reduce cable congestion around compact ports. For better bending performance in base station cabinets and outdoor wireless sites, G.657.A1 bend-insensitive single mode fiber is recommended as the standard configuration.
For projects with stricter optical link budget requirements, FOCC can provide low-loss connector options, such as insertion loss ≤0.3dB and return loss ≥50dB for single mode UPC connections. For general FTTA deployment, standard optical performance such as IL ≤0.5dB can also be selected according to the project requirement.
Before placing an order, customers are advised to confirm the required cable length, fiber type, jacket material, connector configuration, optical performance grade, color, labeling, and packaging method. This helps ensure that the cable assembly matches the actual equipment interface and field installation conditions.
Contact FOCC for Customized FULLAXS Fiber Cable Assemblies
FOCC provides customized FULLAXS LC/UPC Uniboot-LC/UPC Single Mode Patch Cable solutions for telecom contractors, system integrators, wireless network projects, and OEM customers. Cable length, fiber grade, jacket material, connector type, label, packing, and test requirements can be customized according to your project needs.
If you are working on an FTTA, RRH, AAU, BBU/RRU, outdoor wireless, or base station cabinet project, please send us your required specifications. FOCC can help you confirm the suitable cable structure, optical performance level, and production solution before mass order.
Send your inquiry to FOCC to get a customized FULLAXS fiber patch cable solution for your next telecom deployment.
Hot Tags: fullaxs lc/upc uniboot single mode fiber patch cable for rrh and ftta applications, China, factory, suppliers, manufacturers, quotation, customized, price, buy